Used to measure liquid, gas or steam level, density and pressure, and then put it into a 4 ~ 20 mA DC signal output. FY1151/3351 DP intelligent and hand hold is mutual communication HART, through it Settings, monitoring or and upper units into site monitoring system. FY1151/3351 DP field adjustable intelligent difference pressure transmitter is the company according to the requirements developed new products, but from the hand exercise, through the key way realization site for zero, configuration, operation.
1. The performance specifications
(zero benchmark calibration range, reference condition, silicone oil filling liquid, 316 L stainless steel isolated patch.)
1.1. Reference precision
1.1.1. Digital, intelligent: plus or minus 0.1% calibration range
1.1.2. Simulation, linear: plus or minus 0.2% calibration range
1.2. Stability
1.2.1. Digital, intelligent: six months, plus or minus 0.1% URL
1.2.2. Simulation, linear: six months, plus or minus 0.2% URL
1.3. The influence of ambient temperature
1.3.1. Digital, intelligent
Zero error: plus or minus 0.2% URL / 56 ℃
Overall error: ± (0.2% URL + 0.18% calibration range) / 56 ℃
1.3.2. Simulation, linear
Zero error: plus or minus 0.5% URL / 56 ℃
Overall error: ± (0.5% URL + 0.5% calibration range) / 56 ℃
1.4. Static pressure influence
1.4.1. Zero:
For range from four to eight, in 13790 under the kPa more or less 0.2% URL; Other range for plus or minus 0.25% URL. Zero error can be online through the reset to zero corrected.
1.4.2. Range:
Can be modified to plus or minus 0.25% output reading / 6895 kPa, for range 3, can be modified to plus or minus 0.5% output reading / 6895 kPa
1.5. Vibration influence
In any axis up, 200 Hz vibration influence under more or less 0.05% URL/g
1.6. Power influence
Less than plus or minus 0.005% output range/v.
1.7. Load effect:
No load effect, unless the power supply voltage have change.
1.8. / radio frequency interference of electromagnetic interference (EMI/RFI influence)
From 20 to 1000 MHz, the field of to 30 V/M,
Output drift less than-0.1% range.
1.9. Installation position effect
Zero drift is +-0.25 kPa at most. All of the zero drift can be fixed away; The range of no effect.
2. Functions and specifications
2.1. Measurement range: differential pressure: 0-1.3 ~ 6890 KPa
Static pressure: 4, 10 and 14 MPa
2.2. Zero and range
2.2.1. Digital, intelligent:
This machine can range and zero button adjustment, or with hand hold remote adjust the HART.
2.2.2. Simulation, linear:
Range and zero continuous adjustable.
2.3. Zero positive and negative transfer
Zero negative transfer, the lower range must is equal to or greater than-URL; Zero is migration, range limit must be less than or equal to + URL. Calibration range is equal to or greater than the minimum range.
2.4. Output
Digital, intelligent:
4 ~ 20 mA DC, users can choose linear or square root output, digital process variables is in addition to the 4 ~ 20 mA DC signal, are available HART agreement PC use.
Simulation, linear:
4 ~ 20 mA DC, and process the pressure of a linear.
|